Infrastructure / Cooling & resource efficiency

Follow the heat. Define the resource boundary.

An engineering framework for high-density AI infrastructure: rack cooling, final heat rejection, water, electricity and useful compute. These are Aguasto’s evaluation priorities; no operating efficiency result is claimed.

Original Aguasto conceptual illustration. Not manufacturer geometry, an operating Aguasto asset, or a measured benchmark.
The whole thermal path

Liquid at the chip.
A separate choice outside.

Direct-to-chip cooling moves heat from selected components into a technology coolant circuit. A coolant distribution unit can transfer that heat across a controlled interface to the facility circuit.

Other components may still require room air cooling. The facility must ultimately reject heat outside; dry, evaporative and hybrid arrangements have different climate, water, electricity, capacity and maintenance implications.

Warm-water architectures can expand suitable operating options where the exact server, coolant, supply-temperature and ambient envelopes support them. They do not remove the need to validate the selected OEM equipment or establish a universal best design.

Heat rejection / Engineering choices

Follow the heat beyond the closed technology loop.

Two cooling circuits and dry heat rejectionA rack technology loop transfers heat across a CDU heat exchanger to a facility circuit. Final heat rejection and residual air cooling remain separate boundaries. No actual equipment settings or measured water use are shown.Rack / cold platesCDU interfaceDry heat rejectionTechnology coolant circuitFacility heat-transfer circuitResidual air cooling assessed separately
Original generic circuit study. The CDU separates fluids; it does not establish zero site water use. Colors show thermal paths, not measured flow, temperature or a project specification.
Dry heat rejection

Reject heat to air; evaluate the temperature envelope.

Water boundary
Potentially reduces cooling-related local freshwater consumption compared with an evaporative configuration. Other site water uses and indirect electricity-related water remain separate.
Design trade-offs
Ambient conditions, approach temperatures, fan/pump electricity, capacity, space and capital can constrain the choice. Required rack supply conditions must still be met.
Water and climate

A closed loop is
one boundary, not the whole site.

Consumption and withdrawal

Evaporation consumes water. Water withdrawn for use may include returned flows; makeup, blowdown, treatment and source conditions require their own accounting. Annual use cannot establish peak local demand.

Reuse with conditions

Reclaimed water may change freshwater demand where permitted and technically suitable. Quality, treatment, transport, availability and local water conditions need documented assessment.

Climate-specific choices

Dry systems can reduce cooling-related local freshwater use while changing electricity, approach temperatures, space, capital and thermal capacity. Hybrid water assistance needs explicit operating conditions.

Measurement framework

Measure the facility.
Then measure useful work.

Site overhead, local water conditions and quality-qualified model output answer different questions. Comparisons require aligned measurement periods, disclosed equipment and operating boundaries, and reproducible workload conditions.

MetricWhat to measureRequired boundary
PUEFacility energy divided by IT energy over aligned measurement periods.Identify the facility, meters, shared services and reporting period. PUE alone is not useful AI work or a water metric.
WUEDefined facility water use per unit of IT energy, with the applicable reporting boundary stated.Identify units, period, water sources and what the metric includes. Keep withdrawal and consumption visible rather than interchanging them.
Local freshwater consumptionFreshwater consumed within the stated on-site boundary.Separate evaporation and other consumptive uses from withdrawn water that is returned; identify local water conditions.
Peak water withdrawalWater taken from a source over the specified peak interval.Annual averages do not establish peak demand, utility availability or local environmental suitability.
Indirect waterElectricity-related water effects outside the facility boundary.State generation/location/time assumptions. A site cooling claim is not a complete system-wide water footprint.
Cooling electricityMeasured energy for the included pumps, fans, chillers and related systems.Identify which loops, residual air cooling and heat-rejection equipment are counted under the actual climate/load.
Useful compute per kWhQuality-qualified completed work or tokens per the defined energy denominator.Specify checkpoint, request/context distribution, quality, latency, concurrency, errors and included equipment. No Aguasto result is available.
Facility energy per billable workIncluded facility energy per completed commercial workload unit.Separate a metering definition from token billing rules. Idle energy, overhead and failed work need explicit treatment.
Embodied carbon & life cycleA disclosed lifecycle assessment of included construction, equipment, transport and replacement.Declare inventory, service-life assumptions and exclusions. Reuse is not automatically lower impact or indefinitely feasible.

For GPU work and tokens per kWh, pin the checkpoint, runtime, precision, input/output lengths, latency and quality criteria, concurrency, failed work and power metering. Device specifications and token billing are distinct from executed, facility-wide measurements.

Aguasto engineering priorities

Designed for more resource-conscious AI infrastructure.

Evaluate construction, equipment, transport, replacement and end-of-life together. Suitable reuse and modular adaptation can avoid some work, but condition, safety, interface changes and service life determine actual outcomes. Qualified engineering and technical partners would validate functions beyond Aguasto’s established capabilities.

Evidence & methodology

Sources define the questions.
Operating evidence must answer them.

This framework draws on DOE’s facility energy and water guidance, LBNL’s data-center energy/water accounting and ASHRAE’s liquid-cooling system distinctions. Manufacturer material is attributed as vendor guidance; it does not verify an Aguasto result.

DOE FEMP: data centers and servers · LBNL: 2024 energy and water study · ASHRAE: liquid cooling guidance